SECTION 9
EMERGENCY - ELECTRICAL SYSTEM
|
| 1. |
Generator switch - Check on. |
| 2. |
Generator field relay circuit breaker - Reset - One reset only should
be made. |
| 3. |
Generator switch - Reset. If warning light does not go out, proceed
as follows: |
| 4. |
Generator switch - OFF. |
| 5. |
Switch off all unnecessary services. |
| 6. |
Secindary bus reset switch - As desired. |
Note.
The secondary bus is automatically deenergized when one generator fails.
Action (6) is carried
out
only if certain services from the secondary bus are necessary for the flight.
These services are
windshield
heat controls and inverters, main inverter, rear utility receptacles, windshield
wipers, wing
and
tail deicing, pitot heat, cabin and heating, aileron trim control and indicator,
and main inverter relay.
| 7. |
Ammeter - Check for overload. Do not allow ammeter loading for operating
generator to exceed 300 amps. |
| 1. |
Generator switches - check on. |
| 2. |
Generator field relay circuit breaker - Reset - Only one reset should
be made. |
| 3. |
Generator switches - Reset. If warning lights do not go out,
proceed as follows: |
| 4. |
Emergency bus switch - Emergency. |
| 5. |
Battery master switch - OFF. |
Note.
Emergency
bus is now energized from the battery.
CAUTION:With
the emergency bus in operation and battery master switch off, propeller
feathering
pumps
and fuel booster pumps are inoperative.
| 6. |
Switch off any unnecessary services to conserve the battery. |
If
the ammeter for either generator registers zero but other electrical indications
are normal, check for a
faulty ammeter gaga as follows:
| 1. |
Generator switch for appropriate generator - OFF. |
| 2. |
Ammeter - Check for increased reading on ammeter for the other generator. |
| 3. |
Generator switch - Reselect ON if reading increases. An increased reading
will indicate that both generators are operating and that the fault is
in the ammeter circuit. |
| 1. |
Inverter circuit breakers - Reset. |
| 2. |
D.C. power circuit breakers - Reset. |
| 3. |
Inverter switch - Select OFF then return to main. |
| 4. |
If standby light remains out - Leave switch at main. |
| 5. |
If standby light comes on - Select switch to STBY. |
| 1. |
Inverter circuit breakers - Reset. |
| 2. |
D.C. power circuit breakers - Reset. |
| 3. |
Inverter switch - Select OFF then main. |
| 4. |
If the A.C. failure light comes ON - Select inverter switch OFF. |
26 VOLT A.C. TRANSFORMER FAILURE
If the 26 VAC warning light comes on while either inverter is operating
properly, select the instrument
transformer switch from main to standby.
Previous section
Next section
Return to Caribou main page